(a) Type, size, and service pressure. A DOT 4D cylinder is a welded steel sphere (two seamless hemispheres) or circumferentially welded cylinder (two seamless drawn shells) with a water capacity not over 100 pounds and a service pressure of at least 300 but not over 500 pounds per square inchpsig. Cylinders closed in by spinning process are not authorized.
(b) Steel. Open-hearth or electric steel of uniform and weldable quality must be used. Content may not exceed the following: Carbon, 0.25; phosphorus, 0.045; sulphur, 0.050, except that the following steels commercially known as 4130X and Type 304, 316, 321, and 347 stainless steels may be used with proper welding procedure. A heat of steel made under Tabletable 1 in this paragraph (b), check chemical analysis of which is slightly out of the specified range, is acceptable, if satisfactory in all other respects, provided the tolerances shown in Tabletable 2 in this paragraph (b) are not exceeded, except as approved by the Associate Administrator. The following chemical analyses are authorized:
Table 1.—4130X Steel 4130X Percent Carbon 0.25/0.35. Manganese 0.40/0.60. Phosphorus 0.04 max. Sulphur 0.05 max Silicon 0.15/0.35. Chromium 0.80/1.10. Molybdenum 0.15/0.25. Zirconium None. Nickel None.
Table 2.—Authorized Stainless Steels Stainless steels 304 (percent) 316 (percent) 321 (percent) 347 (percent) Carbon (max) 0.08 0.08 0.08 0.08 Manganese (max) 2.00 2.00 2.00 2.00 Phosphorus (max).030.045.030.030 Sulphur (max).030.030.030.030 Silicon (max).75 1.00.75.75 Nickel 8.0/11.0 10.0/14.0 9.0/13.0 9.0/13.0 Chromium 18.0/20.0 16.0/18.0 17.0/20.0 17.0/20.0 Molybdenum 2.0/3.0 Titanium (1) Columbium (2) 1 Titanium may not be less than 5C and not more than 0.60%. 2 Columbium may not be less than 10C and not more than 1.0%.
Table 3.—Check Analysis Tolerances Element Limit or maximum specified (percent) Tolerance (percent) over the maximum limit or under the minimum limit Under minimum limit Over maximum limit Carbon To 0.15 incl 0.01 0.01 Over 0.15 to 0.40 incl.03.04 Manganese To 0.60 incl.03.03 Over 1.15 to 2.50 incl.05.05 Phosphorus 1 All ranges.01 Sulphur All ranges.01 Silicon To 0.30 incl.02.03 Over 0.30 to 1.00 incl.05.05 Nickel Over 5.30 to 10.00 incl.10.10 Over 10.00 to 14.00 incl.15.15 Chromium To 0.90 incl.03.03 Over 0.90 to 2.10 incl.05.05 Over 15.00 to 20.00 incl.20.20 Molybdenum To 0.20 incl.01.01 Over 0.20 to 0.40 incl.02.02 Over 1.75 to 3.0 incl.10.10 Titanium All ranges.05.05 Columbium All ranges.05.05 1 Rephosphorized steels not subject to check analysis for phosphorus.
(c) Identification of material. Material must be identified by any suitable method except that plates and billets for hotdrawn cylinders must be marked with the heat number.
(d) Manufacture. Cylinders must be manufactured using equipment and processes adequate to ensure that each cylinder produced conforms to the requirements of this subpart. No defect is permitted that is likely to weaken the finished container appreciably. A reasonably smooth and uniform surface finish is required. Welding procedures and operators must be qualified in accordance with CGA Pamphlet C-3 (IBR, see § 171
.
7 of this subchapter).
(e) Wall thickness. The wall stress at the minimum test pressure may not exceed 24,000
pounds per square inch
psi
, except where steels commercially known as 4130X, types 304, 316, 321, and 347 stainless steels are used, stress at the test pressures may not exceed 37,000
pounds per square inch
psi
. The minimum wall thickness for any container having a capacity of 1,100 cubic inches or less is 0.04 inch. The minimum wall thickness for any container having a capacity in excess of 1,100 cubic inches is 0.095 inch. Calculations must be done by the following:
(1) Calculation for a “sphere” must be made by the formula:
S
=
PD
/
4tE
Where:
S
=
wall stress in
pounds per square inch
psi
;
P
=
test pressure prescribed for water jacket test, i.e., at least two times service pressure, in
pounds per square inch
psig
;
D
=
outside diameter in inches;
t
=
minimum wall thickness in inches;
E
=
0.85 (provides 85 percent weld efficiency factor which must be applied in the girth weld area and heat affected zones which zone must extend a distance of 6 times wall thickness from center line of weld);
E
=
1.0 (for all other areas).
(2) Calculation for a cylinder must be made by the formula:
S
=
[P(1.
3D2
3D 2
+
0.
4d2
4d 2
)]
/
(
D2
D 2
−
dT12
d T12
)
Where:
S
=
wall stress in
pounds per square inch
psi
;
P
=
test pressure prescribed for water jacket test, i.e., at least two times service pressure, in
pounds per square inch
psig
;
D
=
outside diameter in inches;
d
=
inside diameter in inches.
(f) Heat treatment. The completed cylinders must be uniformly and properly heat-treated prior to tests.
(g) Openings in container. Openings in cylinders must comply with the following:
(1) Each opening in the container, except those for safety devices, must be provided with a fitting, boss, or pad, securely attached to the container by brazing or by welding or by threads. If threads are used, they must comply with the following:
(i) Threads must be clean cut, even, without checks, and tapped to gauge.
(ii) Taper threads must be of a length not less than that specified for American Standard taper pipe threads.
(iii) Straight threads, having at least 4 engaged threads, must have a tight fit and calculated shear strength of at least 10 times the test pressure of the container. Gaskets, adequate to prevent leakage, are required.
(2) Closure of a fitting, boss, or pad must be adequate to prevent leakage.
(h)
Hydrostatic
Pressure
test
testing
. Each cylinder must successfully withstand a
hydrostatic
pressure
test
,
as follows:
(1)
The
Lot
test
testing.
(i) At least one cylinder selected at random out of each lot of 200 or fewer
must be
tested
by water-jacket
,
or
other
direct
suitable
expansion
method,
as
operated
prescribed
so
in
as
CGA
to
C-1
obtain
(IBR;
accurate
see
data
§ 171
.
7
A
of
pressure
this
gauge
subchapter).
must
The
permit
testing
a
equipment
reading
must
to
be
an
calibrated
accuracy
as
of
prescribed
1
in
percent
CGA C-1
.
An
All
expansion
testing
gauge
equipment
and pressure indicating devices
must
permit
be
reading
accurate
of
within
total
the
expansion
parameters
defined in CGA C-1.
(ii) The selected cylinder must be tested
to
an
a
accuracy
minimum
of
either
three
1
(3)
percent
times
or
service
0
pressure
.
1 cubic centimeter.
(
2
iii
)
Pressure
The
minimum test pressure
must be maintained
for
be
maintained
at least 30 seconds and sufficiently longer to ensure complete expansion. Any internal pressure applied after heat-treatment and
previous
prior
to the official test may not exceed 90 percent of the test pressure. If, due to failure of the test apparatus
or operator error
, the test pressure cannot be maintained, the test may be repeated
at
in
a
accordance
pressure
with
increased
CGA
by 10 percent or 100 pounds per square inch
C-1
,
whichever
section
is the lower
5
.
7.2.
(
3
iv
) Permanent volumetric expansion may not exceed 10 percent of the total volumetric expansion at test pressure.
(
4
2
)
Containers
Pressure
testing. (i) The remaining cylinders in each lot
must be tested
by the proof pressure water-jacket or direct expansion test method
as
follows:
prescribed in CGA C-1. The minimum test pressure must be maintained for the specific timeframe and the testing equipment must be calibrated as prescribed in CGA C-1. Further, all testing equipment and pressure indicating devices must be accurate within the parameters defined in CGA C-1. Determination of expansion properties is not required.
(
i
ii
) Each
container
cylinder
must be tested
to
at
a
least
minimum
of two (
2
)
times service pressure
;
and show no defect. If, due to failure of the test apparatus
or
operator error, the test pressure cannot be maintained, the test may be repeated in accordance with CGA C-1 5.7.2 or 7.1.2, as appropriate.
(
ii
3
)
One
Alternative
container
volumetric
out
expansion
of
testing.
each
As
lot
an
alternative to the testing prescribed in paragraphs (h)(1) and (2)
of
200
this
section, every cylinder may be volumetrically expansion tested by the water jacket
or
less
direct
expansion test method. The testing equipment must be calibrated as prescribed in CGA C-1. All testing equipment and pressure indicating devices must be accurate within the parameters defined in CGA C-1.
(i) Each cylinder must be tested
to
a minimum of
at least
3
two
(2)
times
its
service pressure.
(ii)
Others
The
minimum test pressure
must be
examined
maintained
under
at
least 30 seconds and sufficiently longer to ensure complete expansion. Any internal
pressure
applied after heat-treatment and previous to the official test may not exceed 90 percent
of
2
the
times
test
service
pressure.
If, due to failure of the test apparatus or operator error, the test
pressure
and
cannot
show
be
no
maintained,
defects
the test may be repeated in accordance with CGA C-1, section 5
.
7.2.
(
iii) Permanent volumetric expansion may not exceed 10 percent of total volumetric expansion at test pressure.
(
i) Flattening test for spheres and cylinders. Spheres and cylinders must be subjected to a flattening test as follows:
(1) One sphere taken at random out of each lot of 200 or less must be subjected to a flattening test as follows:
(i) The test must be performed after the hydrostatic test.
(ii) The test must be between parallel steel plates on a press with a welded seam at right angles to the plates. Any projecting appurtenances may be cut off (by mechanical means only) prior to crushing.
(2) One cylinder taken at random out of each lot of 200 or less must be subjected to a flattening test, as follows:
(i) The test must be performed after the hydrostatic test.
(ii) The test must be between knife edges, wedge shaped, 60° angle, rounded to 1/2 inch radius. For lots of 30 or less, physical tests are authorized to be made on a ring at least 8 inches long cut from each cylinder and subjected to the same heat treatment as the finished cylinder.
(j) Physical test and specimens for spheres and cylinders. Spheres and cylinders must be subjected to a physical test as follows:
(1) Physical test for spheres are required on 2 specimens cut from a flat representative sample plate of the same heat taken at random from the steel used to produce the sphere. This flat steel from which the 2 specimens are to be cut must receive the same heat-treatment as the spheres themselves. Sample plates must be taken for each lot of 200 or less spheres.
(2) Specimens for spheres must have a gauge length 2 inches with a width not over
11
1 1
/2 inches, or a gauge length at least 24 times the thickness with a width not over 6 times the thickness is authorized when a wall is not over 3/16 inch thick.
(3) Physical test for cylinders is required on 2 specimens cut from 1 cylinder taken at random out of each lot of 200 or less. For lots of 30 or less, physical tests are authorized to be made on a ring at least 8 inches long cut from each cylinder and subjected to the same heat treatment as the finished cylinder.
(4) Specimens for cylinders must conform to the following:
(i) A gauge length of 8 inches with a width not over
11
1 1
/2 inches, or a gauge length of 2 inches with a width not over
11
1 1
/2 inches, or a gauge length at least 24 times the thickness with a width not over 6 times the thickness is authorized when a cylinder wall is not over 3/16 inch thick.
(ii) The specimen, exclusive of grip ends, may not be flattened. Grip ends may be flattened to within 1 inch of each end of the reduced section. Heating of the specimen for any purpose is not authorized.
(5) The yield strength in tension must be the stress corresponding to a permanent strain of 0.2 percent of the gauge length. The following conditions apply:
(i) The yield strength must be determined by either the “offset” method or the “extension under load” method as prescribed in ASTM
Standard
E
E8
8 (IBR, see § 171
.
7 of this subchapter).
(ii) In using the “extension under load” method, the total strain (or “extension under load”) corresponding to the stress at which the 0.2 percent permanent strain occurs may be determined with sufficient accuracy by calculating the elastic extension of the gauge length under appropriate load and adding thereto 0.2 percent of the gauge length. Elastic extension calculations must be based on an elastic modulus of 30,000,000. In the event of controversy, the entire stress-strain diagram must be plotted and the yield strength determined from the 0.2 percent offset.
(iii) For the purpose of strain measurement, the initial strain must be set while the specimen is under a stress of 12,000
pounds
psi
per square inch
and the strain indicator reading being set at the calculated corresponding strain.
(iv) Cross-head speed of the testing machine may not exceed 1/8 inch per minute during yield strength determination.
(k) Acceptable results for physical and flattening tests. Either of the following is an acceptable result:
(1) An elongation of at least 40 percent for a 2 inch gauge length or at least 20 percent in other cases and yield strength not over 73 percent of tensile strength. In this instance, the flattening test is not required.
(2) An elongation of at least 20 percent for a 2 inch gauge length or 10 percent in other cases. Flattening is required to 50 percent of the original outside diameter without cracking.
(l) Rejected cylinders. Reheat-treatment is authorized for rejected cylinders. Subsequent thereto, containers must pass all prescribed tests to be acceptable. Repair of welded seams by welding prior to reheat-treatment is authorized.
(m) Marking. Marking on each container by stamping plainly and permanently are only authorized where the metal is at least 0.09 inch thick, or on a metal nameplate permanently secured to the container by means other than soft solder, or by means that would not reduce the wall thickness.
[Amdt. 178-114, 61 FR 25942, May 23, 1996, as amended at 66 FR 45386, 45388, Aug. 28, 2001; 67 FR 51653, Aug. 8, 2002; 68 FR 75748, Dec. 31, 2003; 85 FR 85426, Dec. 28, 2020]