33 CFR 156.130
Connection.
(a)Each person who makes a connection for transfer operations shall:#
(1)Use suitable material in joints and couplings to ensure a leak-free seal;#
(2)Use a bolt in at least every other hole, and in no case less than four bolts, in each temporary bolted connection that uses a flange that meets American National Standards Institute (ANSI) standard flange requirements under § 154.500(d)(2) of this chapter;#
(3)Use a bolt in each hole in each temporary bolted connection that uses a flange other than one that meets ANSI standards;#
(4)Use a bolt in each hole of each permanently connected flange;#
(5)Use bolts of the correct size in each bolted connection; and#
(6)Tighten each bolt and nut uniformly to distribute the load and sufficiently to ensure a leak free seal.#
(b)A person who makes a connection for transfer operations must not use any bolt that shows signs of strain or is elongated or deteriorated.#
(c)Except as provided in paragraph (d) of this section, no person may use a connection for transfer operations unless it is:#
(1)A bolted or full threaded connection; or#
(2)A quick-connect coupling acceptable to the Commandant.#
(d)No person may transfer oil or hazardous material to a vessel that has a fill pipe for which containment cannot practically be provided unless an automatic back pressure shutoff nozzle is used.#