Regulationhistorical
49 CFR 179.300-17
Tests of safety relief devices.
Snapshot 1998-10-01 Government source
eCFR editorial compilationAuthoritative but unofficial
View source (a) Each valve shall be tested by air or gas before being put into service. The valve shall open and be vapor-tight at the pressure prescribed in § 179.301.
(b) Frangible discs of safety vents must be tested as prescribed in AAR Specifications for Tank Cars, appendix A, A5.03.
(c) For safety relief devices of the fusible plug type, a sample of the plug used shall function at the temperatures prescribed in § 179.300-15.
(d) The start-to-discharge and vapor-tight pressures shall not be affected by any auxiliary closure or other combination.
[29 FR 18995, Dec. 29, 1964. Redesignated at 32 FR 5606, Apr. 5, 1967, and amended by Amdt. 179-10, 36 FR 21355, Nov. 6, 1971]