P-73-035
P-73-035
NTSB safety recommendation P-73-035.
THE NTSB RECOMMENDS THAT THE EXXON PIPE LINE COMPANY: ADD ADDITIONAL CATHODIC PROTECTION EQUIPMENT, BASED UPON THE RESULTS OF THIS SURVEY, TO MITIGATE THE CONTINUING EFFECTS OF CORROSION ON THIS SYSTEM.
Priority: CLASS II
Overall Status: Closed - Acceptable Action
Issued Date: 1973-08-10
Adopted Date: 1973-08-01
Overall Date Closed: 1976-07-20
Synopsis: ON MAY 14, 1972, A SHUTDOWN, CLOSED-IN 8-INCH PIPELINE OWNED BY THE EXXON PIPE LINE COMPANY RUPTURED NEAR HEARNE, TEXAS. THE CRUDE OIL FLOWED ALONG A SMALL STREAM AND WAS DAMMED UP 1 FOOT DEEP IN A STOCK POND 1,800 FEET FROM THE LEAK. VAPORS FROM THE CRUDE OIL, WHICH CONTINUED TO LEAK FROM THE RUPTURE, ENTERED A HOUSE AND WERE IGNITED. THE EXPLOSION KILLED ONE PERSON, SERIOUSLY BURNED TWO OTHERS, DESTROYED THE HOUSE, MELTED NEARBY COMMUNICATION LINES, AND SCORCHED AN 1,800-FOOT-LONG AREA.
Ntsbnumber: PLD72XR003
Report Number: PAR-73-02
Addressee Name: ExxonMobil Corporation
Addressee Status: Closed--No Longer Applicable
Addressee Date Closed: 1976-07-20
Addressee Organization Type: P-Private Industry
Communication Date: 1973-12-20
Communication Type: Official Correspondence
Communication Contents: LETTER FROM EXXON PIPE LINE COMPANY: TWO ADDITIONAL RECTIFIERS AND GROUNDBEDS HAVE BEEN ADDED SINCE THE FAILURE TO SUPPLEMENT THE EXISTING INSTALLATIONS AND PROVIDE CATHODIC PROTECTION TO ALL OF THE LINES IN THE SYSTEM.
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.