P-73-036
P-73-036
NTSB safety recommendation P-73-036.
THE NTSB RECOMMENDS THAT THE EXXON PIPE LINE COMPANY: NOT OPERATE OR CLOSE IN THE COMYN TO SATSUMA SYSTEM FROM HEARNE TO SATSUMA AT A PRESSURE GREATER THAN 400 P.S.I.G., UNTIL AT LEAST THIS SECTION OF LINE HAS BEEN HYDROSTATICALLY TESTED SUCCESSFULLY AND FOUND TO BE SAFE FOR HIGHER OPERATING PRESSURES.
Priority: CLASS II
Overall Status: Closed - Acceptable Action
Issued Date: 1973-08-10
Adopted Date: 1973-08-01
Overall Date Closed: 1976-07-20
Synopsis: ON MAY 14, 1972, A SHUTDOWN, CLOSED-IN 8-INCH PIPELINE OWNED BY THE EXXON PIPE LINE COMPANY RUPTURED NEAR HEARNE, TEXAS. THE CRUDE OIL FLOWED ALONG A SMALL STREAM AND WAS DAMMED UP 1 FOOT DEEP IN A STOCK POND 1,800 FEET FROM THE LEAK. VAPORS FROM THE CRUDE OIL, WHICH CONTINUED TO LEAK FROM THE RUPTURE, ENTERED A HOUSE AND WERE IGNITED. THE EXPLOSION KILLED ONE PERSON, SERIOUSLY BURNED TWO OTHERS, DESTROYED THE HOUSE, MELTED NEARBY COMMUNICATION LINES, AND SCORCHED AN 1,800-FOOT-LONG AREA.
Ntsbnumber: PLD72XR003
Report Number: PAR-73-02
Addressee Name: ExxonMobil Corporation
Addressee Status: Closed--No Longer Applicable
Addressee Date Closed: 1976-07-20
Addressee Organization Type: P-Private Industry
Communication Date: 1973-12-20
Communication Type: Official Correspondence
Communication Contents: LETTER FROM EXXON PIPE LINE COMPANY: THE SPECIFIC PIPELINE SECTION THAT EXPERIENCED THE FAILURE, NO. 6-8 INCH BETWEEN HEARNE AND CLAY GATE PLANT HAS BEEN REPAIRED AT THE POINT OF FAILURE, INSPECTED BY A LINALOG SURVEY, FILLED WITH DRY NITROGEN AND REMOVED FROM SERVICE. AT PRESENT WE HAVE NO PLANS TO RETURN THE LINE TO SERVICE.
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.