P-82-019
P-82-019
NTSB safety recommendation P-82-019.
AS A RESULT OF THIS INVESTIGATION, THE NTSB RECOMMENDS THAT THE AMERICAN GAS ASSOCIATION AND THE INTERSTATE NATURAL GAS ASSOCIATION OF AMERICA: URGE MEMBER COMPANIES TO PARTICIPATE IN THE CURRENT EFFORT TO ESTABLISH A "ONE-CALL" NOTIFICATION SYSTEM IN THE STATE OF TEXAS.
Priority: CLASS II
Overall Status: Closed - Acceptable Action
Issued Date: 1982-06-09
Adopted Date: 1982-04-20
Overall Date Closed: 1982-10-22
Synopsis: ON SEPTEMBER 27, 1981, NEAR ACKERLY, TEXAS, THE CHAPPARRAL PIPELINE, A REFINED PETROLEUM PRODUCTS 12-INCH STEEL PIPE LINE OWNED BY THE SANTA FE PIPELINE COMPANY, WAS DAMAGED BY A RATHOLE DRILL BIT; THE WALL OF THE PIPE WAS WEAKENED, AND IT RUPTURED UNDER THE 1,100 PSIG OPERATING PRESSURE. THE ETHANE-PROPANE MIXTURE IN THE PIPELINE BEGAN TO ESCAPE AND WAS IGNITED BY THE DRILLING RIG ENGINE. THE ENSUING EXPLOSION AND FIRE KILLED THREE PERSONS; CRITICALLY BURNED ONE PERSON, WHO DIED 4 DAYS LATER; DESTROYED THE RATHOLE DRILLING RIG, A PICKUP TRUCK, A ROAD GRADER, A COMPACTOR, AND 60 ACRES OF COTTON; AND BURNED 12,749 BARRELS (535,458 GALLONS) OF ETHANE-PROPANE MIXTURE. THIS IS NOT AN ISOLATED INCIDENT; THERE HAVE BEEN OTHER SIMILAR PIPELINE ACCIDENTS INVOLVING DRILLING ACTIVITIES. THE SAFETY BOARD IS CONCERNED ABOUT THE DAMAGE TO PIPELINES CAUSED BY DRILLING ACTIVITIES AND THE USE OF OUTSIDE EXCAVATION EQUIPMENT SINCE THE LOCATION OF A PIPELINE CAN BE ASCERTAINED IN SEVERAL WAYS. THE EFFECTIVENESS OF THE "ONE-CALL" NOTIFICATION SYSTEM HAS BEEN PROVEN; HOWEVER, NO STATEWIDE, "ONE-CALL" SYSTEM EXISTS IN TEXAS. CURRENT EFFORTS BY THE PIPELINE INDUSTRY NO FORMULATE AND IMPLEMENT A "ONE-CALL" SYSTEM IN THE STATE OF TEXAS MERIT THE SUPPORT OF THE ENTIRE PETROLEUM INDUSTRY.
Probable Cause: None
Ntsbnumber: DCA81MP023
Report Number: PAR-82-02
Addressee Name: American Gas Association
Addressee Status: Closed--No Longer Applicable
Addressee Date Closed: 1982-10-22
Addressee Acronym: AGA
Addressee Organization Type: A-Associations
Communication Date: 1982-08-02
Communication Type: Official Correspondence
Communication Contents: AMERICAN GAS ASSOCIATION LETTER TO MEMBER COMPANY DELEGATES REGARDING NTSB SAFETY RECOMMENDATION P-82-19: GENTLEMEN ENCLOSED FOR YOUR INFORMATION IS A COPY OF THE NTSB SAFETY RECOMMENDATION CONCERNING THE INCIDENT NEAR ACKERLY, TEXAS, ON SEPTEMBER 27, 1981. THE COORDINATING GROUP FOR PIPELINE SAFETY RECOMMENDS THAT THE ATTACHED BE DISTRIBUTED TO APPROPRIATE PERSONNEL WITHIN EACH COMPANY. THE AMERICAN GAS ASSOCIATION SUPPORTS EFFORTS TO IMPROVE SAFETY WITHIN THE INDUSTRY, AND HOPES THAT THIS RECOMMENDATION WILL BE OF SOME ASSISTANCE TO YOU.
Addressee Acronym: AGA
Addressee Organization Type: A-Associations
Communication Date: 1982-10-08
Communication Type: Official Correspondence
Addressee Name: Interstate Natural Gas Association of America
Addressee Status: Closed--No Longer Applicable
Addressee Date Closed: 1982-10-22
Addressee Acronym: INGAA
Addressee Organization Type: A-Associations
Communication Date: 1982-06-21
Communication Type: Official Correspondence
Communication Contents: INGAA LTR: THIS RECOMMENDATION WAS FORWARDED TO INGAA MEMBERSHIP ON JUNE 21, 1982. THE JUNE 25, 1982, INGAA "WASHINGTON REPORT" CONTAINED AN ITEM ON THIS ACCIDENT.
Addressee Acronym: INGAA
Addressee Organization Type: A-Associations
Communication Date: 1982-10-22
Communication Type: Official Correspondence