P-86-010
P-86-010
NTSB safety recommendation P-86-010.
THE NTSB RECOMMENDS THAT THE CONTINENTAL PIPE LINE COMPANY: BASED ON THE RESULTS OF THE JOB/TASK ANALYSIS, DEVELOP AND CONDUCT SELECTION AND TRAINING PROGRAMS TO PRODUCE EMPLOYEES AND CONTRACTOR PERSONNEL WHO ARE PROPERLY QUALIFIED AND TRAINED TO PERFORM THE PIPELINE RECOATING OPERATIONS.
Priority: CLASS II
Overall Status: Closed - Acceptable Action
Issued Date: 1986-04-17
Adopted Date: 1986-03-18
Overall Date Closed: 1989-07-12
Synopsis: ABOUT 10:30 A.M. ON JULY 23, 1985, IN A RURAL AREA ABOUT 8 MILES SOUTH OF KAYCEE, WYOMING, A GIRTH WELD CRACKED DURING A PIPELINE RECOATING PROJECT ON A 23-YEAR-OLD, 8-INCH DIAMETER PIPELINE OWNED BY THE CONTINENTAL PIPE LINE COMPANY. THE CRACKED GIRTH WELD ALLOWED THE RELEASE, ATOMIZATION, AND IGNITION OF AIRCRAFT TURBINE FUEL UNDER 430 POUNDS PRESSURE, KILLING ONE PERSON, BURNING SIX PERSONS, DESTROYING CONSTRUCTION EQUIPMENT, AND SHUTTING DOWN THE PIPELINE. DAMAGE WAS ESTIMATED AT MORE THAN $128,000.
Probable Cause: None
Keywords: Training and Education
Ntsbnumber: DCA85FP016
Report Number: PAR-86-01
Addressee Name: Continental Pipeline Company
Addressee Status: Closed - Acceptable Action
Addressee Date Closed: 1989-07-12
Addressee Organization Type: P-Private Industry
Communication Date: 1988-12-27
Communication Type: Official Correspondence
Communication Contents: CPL'S WESTERN DIVISION BEGAN IN 1987 TO CONDUCT INSPECTOR SCHOOLS DURING THE FIRST QUARTER OF EACH YEAR. EVEN THOUGH CPL UTILIZES INDEPENDENT CONTRACTORS TO PERFORM ITS PIPE LINE RECONDITIONING, THE CONTRACTOR IS REQUIRED TO PRESENT THE SPECIFIC PRACTICES TO BE EMPLOYED WHEN HANDLING A LIVE PIPELINE.
Addressee Organization Type: P-Private Industry
Communication Date: 1988-11-08
Communication Type: Official Correspondence
Addressee Organization Type: P-Private Industry
Communication Date: 1989-07-12
Communication Type: Official Correspondence
Addressee Organization Type: P-Private Industry
Communication Date: 1988-10-21
Communication Type: Official Correspondence
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.