CPF 220051005
CPF 220051005
220051005_final order_11282005_text.pdf, page 1Official PDFU. S. Department of rra nsportation pipeline ond Hazardous Moterlots safe+ Admlnlstrokon 400 Seventh Street, S. W. Washington, D. C. 20590 IIOV 28 I60ti Mr. David Jones Vice President, Eastern Operations Tennessee Gas Pipeline Company an affiliate of El Paso Corporation P. O. Box 2511 Houston, TX 77001 RE: CPF No. 2-2005-1005 Dear Mr. Jones: Enclosed is the Final Order issued by the Associate Administrator for Pipeline Safety in the above-referenced case. It makes a finding of violation and assesses a civil penalty of $15, 000. I acknowledge receipt of, and accept payment dated April 18, 2005 in the amount of $15, 000 as payment in full of the civil penalty assessed against Tennessee Gas Pipeline Company in the Final Order. This case is now closed. Your receipt of the Final Order constitutes service of that document under 49 C. F. R. II 190. 5. Sincerely, James Reynolds Pipeline Compliance Registry Office of Pipeline Safety Enclosure cc: Ms. Linda Daugherty, Director, OPS Southern Region CERTIFIED MAIL - RETURN RECEIPT RE UESTED gllCki ~ Ifl 4 ~'v, 5#
220051005_final order_11282005_text.pdf, page 2DEPARTMENT OF TRANSPORTATION PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION OFFICE OF PIPELINE SAFETY WASHINGTON, D. C. 20590 In the Matter of Tennessee Gas Pipeline Company, Aa Affiliate of El Paso Corporation Respondent. CPF No. 2-2005-1005 Southern FINAL ORDER Between May 10, 2004 and November 4, 2004, pursuant to 49 U. S. C. $ 60117, a representative of the Office of Pipeline Safety (OP S), Region conducted an on-site pipeline safety inspection of Respondent's facilities in Mississippi, Alabama, and Kentucky and reviewed records at the Heidelberg, Mississippi; Columbus, Mississippi; Catlettsburg, Kentucky; Clay City, Kentucky and Campbellsville, Kentucky offices. As a result of the inspection, the Director, Southern Region, OPS, issued to Respondent, by letter dated March 8, 2005, a Notice of Probable Violation and Proposed Civil Penalty (Notice). In accordance with 49 C. F. R, $ 190. 207, the Notice proposed finding that Respondent had committed violations of 49 C. F. R. Part 192 and proposed assessing a civil penalty of $15, 000 for the alleged violations. Respondent responded to the Notice by letter dated April 15, 2004 (Response). Respondent did not contest the allegation of violation, but offered information to explain the allegations and provided information concerning the corrective actions it has taken. Respondent did not request a hearing, and therefore has waived the right to one. FINDINGS OF VIOLATION Uncontested Respondent did not contest the alleged violation of )192. 739(a) in the Notice. Accordingly, I find that Respondent violated 49 C. F. R. Part 192, as more fully described in the Notice, 49 C. F. R. I'1192. 739(a) — failure to inspect and test each pressure limiting station, relief device, and pressure regulating, and pressure regulating station and its equipment at intervals not exceeding 15 months, but at least once each calendar year. Respondent failed to demonstrate that pressure limiting and relief devices were being inspected and tested at fifteen supplier delivery locations in the Heidelberg, Mississippi area and at fourteen locations in Columbus, Mississippi. This finding of violation will be considered a prior offense in any subsequent enforcement action taken against Respondent.#
220051005_final order_11282005_text.pdf, page 3ASSESSMENT OF PENALTY Under 49 U. S. C. tj 60122, Respondent is subject to a civil penalty not to exceed $100, 000 per violation for each day of the violation up to a maximum of $1, 000, 000 for any related series of violations. The Nonce proposed a $15, 000 civil penalty for violation of 49 C. F. R. tj 192. 739(a). 49 U. S. C. tj 60122 and 49 C. F. R. $ 190. 225 require that, in determining the amount of the civil penalty, I consider the following criteria: nature, circumstances, and gravity of the violation, degree of Respondent's culpability, history of Respondent's prior offenses, Respondent's ability to pay the penalty, good faith by Respondent in attempting to achieve compliance, the effect on Respondent's ability to continue in business, and such other matters as justice may require. The Notice proposed a civil penalty of $15, 000, as Respondent failed to inspect a", d test each pressure limiting station and relief device at fifteen supplier delivery locations in the Heidelberg, Mississippi area and at fourteen locations in Columbus, Mississippi, at intervals not exceeding 15 months, but at least once each calendar year, as required by 49 C. F. R. Ij192. 739(a). Respondent did not contest the allegation of violation. Accordingly, having reviewed the record and considered the assessment criteria, I assess Respondent a civil penalty of $15, 000, already paid by the Respondent for violation. WARNING ITEMS The Notice did not propose a civil penalty or compliance action for Items 1, 3, and 4 in the Notice; therefore, these are considered warning items. Respondent is warned that if it does not take appropriate action to correct these items, enforcement acuon will be taken i f a subsequent inspection reveals a violation. s and conditions of this Final Order are effective on receipt. NOV 28 Zpli Date Issued ciao Administrator PipeHne Safety#
Final Order Tennessee Gas Pipeline Company CPF No 2-2005-1005.pdf, page 1Official PDFUS. Department of Transportation Pipeline and Hazardous Materials Safety Administration 400 Seventh Street, S.W. Washington, D.C. 20590 Mr. David Jones Vice President, Eastern Operations Tennessee Gas Pipeline Company an affiliate of El Paso Corporation P.O. Box 251 1 Houston, TX 77001 RE: CPF NO. 2-2005- 1005 Dear Mr. Jones: Enclosed is the Final Order issued by the Associate Administrator for Pipeline Safety in the above-referenced case. It makes a finding of violation and assesses a civil penalty of $15,000. I acknowledge receipt of, and accept payment dated April 18,2005 in the amount of $1 5,000 as payment in full of the civil penalty assessed against Tennessee Gas Pipeline Company in the Final Order. This case is now closed. Your receipt of the Final Order constitutes service of that document under 49 C.F.R. $ 190.5. Sincerely, James Reynolds Pipeline Compliance Registry Office of Pipeline Safety Enclosure cc: Ms. Linda Daugherty, Director, OPS Southern Region CERTIFIED MAIL - RETURN RECEIPT REQUESTED#
Final Order Tennessee Gas Pipeline Company CPF No 2-2005-1005.pdf, page 2DEPARTMENT OF TRANSPORTATION PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION OFFICE OF PIPELINE SAFETY WASHINGTON, D.C. 20590 In the Matter of ) Tennessee Gas Pipeline Company, 1 ) CPF No. 2-2005-1005 An Affiliate of El Paso Corporation Respondent. FINAL ORDER Between May 10,2004 and November 4,2004, pursuant to 49 U.S.C. 5 601 17, a representative of the Office of Pipeline Safety (OPS), Southern Region conducted an on-site pipeline safety inspection of Respondent's facilities in Mississippi, Alabama, and Kentucky and reviewed records at the Heidelberg, Mississippi; Columbus, Mississippi; Catlettsburg, Kentucky; Clay City, Kentucky and Campbellsville, Kentucky offices. As a result of the inspection, the Director, Southern Region, OPS, issued to Respondent, by letter dated March 8, 2005, a Notice of Probable Violation and Proposed Civil Penalty (Notice). In accordance with 49 C.F.R. $ 190.207, the Notice proposed finding that Respondent had committed violations of 49 C.F.R. Part 192 and proposed assessing a civil penalty of $15,000 for the alleged violations. Respondent responded to the Notice by letter dated April 15,2004 (Response). Respondent did not contest the allegation of violation, but offered information to explain the allegations and provided information concerning the corrective actions it has taken. Respondent did not request a hearing, and therefore has waived the right to one. FINDINGS OF VIOLATION Uncontested Respondent did not contest the alleged violation of $ l92.739(a) in the Notice. Accordingly, I find that Respondent violated 49 C.F.R. Part 192, as more fully described in the Notice: 49 C.F.R. $192.739(a)-failure to inspect and test each pressure limiting station, relief device, and pressure regulating, and pressure regulating station and its equipment at intervals not exceeding 15 months, but at least once each calendar year. Respondent failed to demonstrate that pressure limiting and relief devices were being inspected and tested at fifteen supplier delivery locations in the Heidelberg, Mississippi area and at fourteen locations in Columbus, Mississippi. This finding of violation will be considered a prior offense in any subsequent enforcement action taken against Respondent.#
Final Order Tennessee Gas Pipeline Company CPF No 2-2005-1005.pdf, page 3ASSESSMENT OF PENALTY Under 49 U.S.C. 5 60122, Respondent is subject to a civil penalty not to exceed $100,000 per violation for each day of the violation up to a maximum of $1,000,000 for any related series of violations. The Notice proposed a $15,000 civil penalty for violation of 49 C.F.R. 9 192.739(a). 49 U.S.C. $ 60122 and 49 C.F.R. 9 190.225 require that, in determining the amount of the civil penalty, I consider the following criteria: nature, circumstances, and gravity of the violation, degree of Respondent's culpability, history of Respondent's prior offenses, Respondent's ability to pay the penalty, good faith by Respondent in attempting to achieve compliance, the effect on Respondent's ability to continue in business, and such other matters as justice may require. The Notice proposed a civil penalty of $15,000, as Respondent failed to inspect and test each pressure limiting station and relief device at fifteen supplier delivery locations in the Heidelberg, Mississippi area and at fourteen locations in Columbus, Mississippi, at intervals not exceeding 15 months, but at least once each calendar year, as required by 49 C.F.R. 9 l92.739(a). Respondent did not contest the allegation of violation. Accordingly, having reviewed the record and considered the assessment criteria, I assess Respondent a civil penalty of $15,000, already paid by the Respondent for violation. WARNING ITEMS The Notice did not propose a civil penalty or compliance action for Items 1,3, and 4 in the Notice; therefore, these are considered warning items. Respondent is warned that if it does not take appropriate action to correct these items, enforcement action will be taken if a subsequent inspection reveals a violation. T e m s and conditions of this Final Order are effective on receipt. fi ta ey erard fi Administrator Pipeline Safety NOV 2 8 a005 Date Issued#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.