PHMSA Guidance, Is Your Cylinder Safe To Fill?
PHMSA Guidance, Is Your Cylinder Safe To Fill?
Portal detail 1Is Your Cylinder Safe To Fill? Is-Your-Cylinder-Safe-to-Fill-PHH50-0201-0323.pdf (315.51 KB) Cylinders that are in poor condition or have not been requalified put you at risk of property damage, severe injuries, or death. Effective Date: Thursday, March 30, 2023#
Attachment 1, passage 1IS YOUR CYLINDER SAFE TO FILL? Cylinders that are in poor condition or have not been requalified put you at risk of property damage, severe injuries, or death. Do not fill any cylinder with: y Excessive rust, corrosion, or pitting on the cylinder, particularly near bottom; y Dents, bulges, cuts or cracks in the surface; y Missing or damaged cylinder footring, cylinder neckring (collar), or valve cover; or y A leaking or defective valve or pressure relief device. If the cylinder looks safe, check the manufacturing and requalification dates to make sure it can be refilled. Manufacturing Date Cylinders must be requalified within 12 years of manufacture (in this illustration by May 2022). Requalification Date If a cylinder is older than 12 years, look for a “requalification date” stamp or sticker. Type of Inspection V123456 0422 E Requalifier ID Number Month/Year requalified This illustration indicates a visual inspection with a requalification period of five years or by April 2027. Other possible requalification markings see 49 CFR 180.213(f): A1 4 22E 32 “E” means the cylinder was requalified by visual inspection only, and must be requalified within 5 years (by April 2027 in this example). A1 4 22S 32 “S” means the cylinder was requalified by proof pressure test, and so must be requalified within 10 years (by April 2032 in this example). A1 4 22 32 No letter after the requalification date means the cylinder was requal- ified by volumetric expansion test, and so must be requalified within 12 years (by April 2034 in this example). Refer to 49 CFR 180.209 and 180.213 for the regulatory text. If you have questions, contact the Hazmat Info Center: 1-800-467-4922 Propane cylinders must periodically be requalified—tested or examined by a cylinder safety expert approved by DOT—to be safe for use. A list of US DOT approved requalifiers and their ID number (RIN) is available on the PHMSA website: https://www.phmsa.dot.gov/hazmat/pressure-vessels- approvals/cylinder-requalifiers. See also 49 CFR 173.301. For additional information contact the Hazardous Materials Info Center Pipeline and Hazardous Materials Safety Administration 1200 New Jersey Ave. SE, East Building, 2nd Floor, Washington, DC 20590 1-800-HMR-4922 (1-800-467-4922) Email: infocntr@dot.gov http://www.phmsa.dot.gov PHH50-0201-0323 The contents of this guide do not have the force and effect of law and are not meant to bind the public in any way, and the guide is intended only to provide information to the public regarding existing requirements under the Hazardous Materials Regulations.#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.