PHMSA Hazmat Incident E-2005100221
PHMSA Hazmat Incident E-2005100221
Incident E-2005100221PHMSA hazardous materials incident report E-2005100221. Incident date: 2005-10-04. Location: ROME, GA. Mode: Rail. Carrier/reporter: BOC Gases. Shipper: BOC Gases. Materials: UN2187; CARBON DIOXIDE, REFRIGERATED LIQUID; hazard class 2.2; 5250 LGA released. What failed: Hose Adaptor or Coupling. How failed: Torn Off or Damaged. Reported failure causes: Vehicular Crash or Accident Damage. Reported result: Vapor(Gas) Dispersion. Reporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.