PHMSA Report 20140071
PHMSA Report 20140071
Gas transmission and gathering incident in MIDLAND, MARTIN County, TX. Reported cause: EQUIPMENT FAILURE. Reported consequences: 1 fatalities, 0 injuries, 0 NATURAL GAS released, $1,400 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.
Report number: 20140071.
Operator ID: 31968.
Reported incident date: 6/1/2014 19:45.
Cause detail: THREADED CONNECTION/COUPLING FAILURE
Cause detail: WTG GAS TRANSMISSION COMPANY WAS IN THE PROCESS OF DE-PRESSURING COMPRESSOR UNIT #7 TO PERFORM MAINTENANCE ON THE UNIT. AN EMPLOYEE BEGAN OPENING THE 2' BLOW-DOWN, RELEASING GAS TO THE ATMOSPHERE. DURING THE VENTING PROCESS, A SCREWED FITTING SEPARATED, WITH A PART OF THE LOOSE VENT PIPING FATALLY STRIKING THE EMPLOYEE. THE VENT VALVE WAS CLOSED SECURING THE RELEASE.
PHMSA trend classification: significant incident, serious incident.
PHMSA standardized cause: EQUIPMENT FAILURE — THREADED CONNECTION/COUPLING FAILURE.
PHMSA indexed costs: $7,970 reported total cost, $4,886.605 in 1984 dollars, $8,130.389 in current-year dollars.
PHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.