PHMSA Report 20100179
PHMSA Report 20100179
Hazardous liquid incident in PICKRELL, GAGE County, NE. Reported cause: MATERIAL FAILURE OF PIPE OR WELD. Reported consequences: 0 fatalities, 0 injuries, 0.36 HVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBIENT CONDITIONS released, $113,311 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.
Report number: 20100179.
Operator ID: 12105.
Reported incident date: 7/23/2010 14:05.
Location detail: 153.4
Cause detail: DESIGN-, CONSTRUCTION-, INSTALLATION-, OR FABRICATION-RELATED
Cause detail: WELDER WAS TACKING A TOR FITTING ONTO THE LINE TO ASSIST IN RELIEVING VAPORS IN THE PIPE AS PART OF THE PROCESS OF EMPTYING CONTENTS OF PIPE IN PREPARATION FOR CONDUCTING A HYDROSTATIC TEST OF THE PIPELINE SEGMENT WHEN THE PIPE BEGAN MOVING AND MAKING A NOISE. THE PIPE SUBSEQUENTLY EMERGED FROM THE EXCAVATED TRENCH AND BOWED, CREAKING A CRACK ON THE BOTTOM OF THE PIPE. THE PIPE SEGMENT WAS REMOVED FROM THE LINE AND SENT FOR METALLURGICAL ANALYSIS. REPAIR WAS MADE BY INSTALLING A NEW PIECE OF PIPE AND THE HYDROSTATIC TEST CONTINUED.
PHMSA trend classification: significant incident, not serious.
PHMSA standardized cause: MATERIAL FAILURE OF PIPE OR WELD — CONSTRUCTION, INSTALLATION OR FABRICATION-RELATED.
PHMSA indexed costs: $163,161 reported total cost, $89,275.814 in 1984 dollars, $219,858.854 in current-year dollars.
PHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.