07-0032
07-0032
Page 1f Transportatio .S. Departmer Washington, D.C. 20590 400 Seventh Street. S.W. Pipeline and Hazardous Materials Safety Administration APR 23 3W7 Mr. James. T. Osterhaus Reference No. 07-0032 Safety Division, Railroad LPG Program Manager Commission of Texas 1701 North Congress P. O. Box 12967 Austin, Texas 78711 Dear Mr. Osterhaus: This is in response to your recent e-mail and telephone conversation with a member of my staff concerning a MC 331 bobtail cargo tank owned by Henderson Butane of 401 North Highway (flammable gas)" and was involved in a rollover accident in Texas on January 17, 2007. 156, P.O. Box 5, Justin, TX 76247, that contained "UN 1075, Petroleum gases, liquified, 2.1 required under § 173.315(n) of the Hazardous Materials Regulations (HMR: 49 CFR Parts 171- You state the cargo tank was not equipped with an emergency discharge control equipment as inspection report prepared by Ricky Taylor of D.L. Morrison Welding and Construction 180) and asked if it should be in service. You supplied a copy of the cargo tank test and Company, 217 Morrison Hill Lane, Gainesville, TX 76240-1619. CT Identification No. 2990, that states the cargo tank was inspected and certified as meeting requirements for service on July 22, 2004. You also asked if a penalty will be assessed against the inspector. The Federal Motor Carrier Safety Administration (FMCSA) is responsible for ensuring the compliance of "cargo tank facilities," which includes cargo tank manufacturers, owners, and inspectors, as well as enforcement matters concerning these devices and individuals under FMCSA regulations and the HMR. Therefore, we are forwarding your letter for response to Mr. James O. Simmons. Chief. Hazardous Materials Division. Office of Enforcement and Room 2328. 400 7" Street, SW., Washington. DC. 20590, (202) 493-0496. Compliance, Federal Motor Carrier Safety Administration. U.S. Department of Transportation. I hope this satisfies your request. Sincerely. !! Hattie L. Mitchell, Chief 113.315(1) Regulatory Review and Reinvention Office of Hazardous Materials Standards 070032#
Page 2CC: James O. Simmons Chief, Hazardous Materials Division Office of Enforcement and Compliance Federal Motor Carrier Safety Administration U.S. Department of Transportation#
Page 301/26/07 11:49 FAX 512 463 7153 RRC SAFETY DIVISION Edmonson 40002 5180.417 (b)c) $173.315 (n Cargo Tanks Request for Interpretation of 49 CFR § 180.417 (b)(2)(viii) 07-0032 Please see Tanker Test and Inspection Report in this fax, listing the owner & carrier of an MC331 Cargo tank as Henderson Butane. This bobtail cargo tank (East Fab, Inc./scrial number - 12135-3) was involved in a rollover accident on 1-17-07 An inspector of the Railroad Commission of Texas conducted an inspection of the bobtail equipment required per 49 CFR § 173.315(n). Specifically, the cargo tank was not and discovered the cargo tank was not provided with the emergency discharge contro provided with an off-truck remote means to close the internal self-closing stop valve(s) and shut off all motive and auxiliary power equipment. 04. He indicates on the Tanker Test and Inspection Report that the cargo tank MEETS The cargo tank was pressure tested (hydrostatic test) by Ricky Taylor, CT2990, on 7-22- THE REQUIRMENTS OF THE DOT SPECIFICATIONS IDENTIFIED ON THIS REPORT. That specification is MC 331. However, without the emergency off-truck remote required to be installed per 49 CFR § 173.315(n)(5)(ii), this cargo tank did NOT meet the requirements of the DOT specification (MC331) specified on the report. In Texas, the Railroad Commission regulates the retail/wholesale LPG businesses and establishes and/or adopts safety rules for LP-Gas. The commission has adopted 49 CFR Our inspection staff has found numerous bobtail delivery trucks (less than 3,500 gallons) that are marked with the correct test dates, but are not equipped with emergency discharge equipment as required by 49 CFR § 173.315(n). me know if the cargo tank shown on the Tanker Test and Inspection Report should have Would someone at DOT please review the attached tanker test & inspection report and let been in service? If it should not have been in service, will DOT consider assessing a penalty against the CT who signed the report and/or the company operating the cargo tank? Thank You, James T. Osterhaus LPG Program Manager Safety Division Railroad Commission of Texas Phone: 512-463-6692 Fax: 512-463-7319 James.Osterhaus@rrc.state.tx.us#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.