Page 1U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration MAR 1 7 2008 1200 New Jersey Avenue, SE Washington, D.C. 20590 Mr. Nick Paulick Director of Engineering Bremer Tank LLC P.O. Box 670 (54936-0670) 450 Arlington Ave. Fond du Lac, WI 54935 . Ref. No.: 07-0228 Dear Mr. Paulick: This is in response to your letter dated November 29,2007 regarding the modification of an MC 307 cargo tank motor vehicle in accordance with the Hazardous Materials Regulations (HMR; 49 CFR Parts 171 - 1 80). Specifically, you ask if the requirements for modifying a cargo tank in 8 180.413(d) would require a shortened MC 307 cargo tank to be subject to the HMR as a DOT 407 cargo tank. You indicate that no new material or equipment would be added to the cargo tank motor vehicle. As defined in 8 180.403, shortening of an MC 307 cargo tank involves a modification to the original design that affects the structural integrity and lading retention capability of the cargo tank. In addition, this modification is also a repair, as defined in 8 180.403, because welding is required to return the cargo tank to specification. The modification and repair must conform with 8 180.413. As provided in 8 180.41 3(d)(2), new materials must meet the DOT 407 specification in effect at the time of the modification. However, in accordance with you letter, no new material will be added to the cargo tank motor vehicle. Therefore, the modification and repair described in your letter may be made in accordance with either Specification DOT 407 or MC 307. You should note that 8 180.413(d)(l) requires certification in writing by a Design Certifying Engineer and $8 180.41 3(b) and (d)(4) require certification by a Registered Inspector in accordance with the most recent version of the original specification or in accordance with the DOT 407 specification in effect at the time of the repair. In addition, the cargo tank must be recertified in accordance with 8 180.405. I hope this information is helpfbl. If you have finther questions, please do not hesitate to contact this office. Chief, Standards Development Office of Hazardous Materials Standards#
Page 2Page 1 of 1 Drakeford, Carolyn <PHMSA> From: Gorsky, Susan <PHMSA> Sent: Friday, November 30,2007 7: 1 1 AM To: Drakeford, Carolyn <PHMSA> Subject: FW: stretching per 180.41 3 Attachments: image001 .png; image004.jpg Please assign this as an interp. Thanks. . .. . , ..07 From: Nick J Paulick [mailto:NJPaulick@brennertank.com] Sent: Thursday, November 29,2007 4:28 PM To: Gorsky, Susan <PHMSA> Cc: Staniszewski, Stanley <PHMSA> Subject: stretching per 180.413 Ms. Gorsky, If I stretch a MC307, it is my understanding that any NEW materials must meet the requirements of 178.345-3, as indicated in 180.413(d)(2) However, if we're making the tank shorter, we would not be adding any new materials, so we would only need to verify that it meets the structural integrity and accident damage protection requirements of the applicable specification (which I read to be MC307). Could you please verify if this is your understanding? FYI, I have spoken with Mr. Joe DeLorenzo and Mr. Stan Staniszewski about this. It appears the DOT'S opinion on this matter is less than black-and-white. Perhaps you could shed some light? Nick Nick Paulick, PE Director of Engineering Brenner Tank LLC Ph: 920-322-1 054 Fx: 920-322-1 084 ~:brennne_rt_a_nkccoom_ Phone 920.322.1054 / Toll Free 800.558.9750 / Fax 920.322.1084 E-mail nieau!~~~@~~~!!ne!3an_k.~c.~.mm CONFIDENTIALITY NOTICE: This e-mail may contain confidential andlor privileged injormation. Ifyou are not the intended recipient (or have received this e-mail in error) please notrJL the sender immediately and destroy this e-mail. Any unauthorized copying, disclosure or distribution ofthe material in this e-mail is strictly forbidden.#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.