08-0216
08-0216
Page 1U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration 1200 New Jersey Ave., SE Washington, DC 20590 Mr. Chris W. Gibson EHS&R Manager Hawkins, Inc. 3 100 East Hennepin Avenue Minneapolis, MN 554 13 Ref. No.: 08-02 16 Dear Mr. Gibson: This responds to your letter dated August 20,2008, regarding the segregation requirements of the Hazardous Materials Regulations (HMR: 49 CFR Parts 17 1 - 1 80). Specifically, you ask if § 177.848(c) applies to the transport of "Hydrochloric Acid, 8, UN 1789, PG 11", and an unregulated material (i.e., Ferric Ferro cyanide) that can produce hydrogen cyanide when it comes into contact with acids. Paragraph (c) of 9 177.848 prohibits cyanides and cyanide mixtures or solutions to be stored, loaded or transported in the same transport vehicle with "acids" if a mixture of the materials would generate hydrogen cyanide. Further, Division 4.2 materials may not be stored, loaded and transported with Class 8 (Corrosive) liquids. This requirement does not address cyanides and cyanide mixtures or solutions transported on the same transport vehicle with unregulated materials. However, 9 173.2 l(e) of the HMR prohibits a material in the same packaging, freight container, or overpack with another material, the mixing of which is likely to cause a dangerous evolution of heat, or flammable or poisonous gases or vapors or to produce corrosive materials. Therefore, the transport of "Hydrochloric Acid, 8, UN 1789, PG 11" and an unregulated material (i.e., Ferric Ferro cyanide) that can produce hydrogen cyanide gases or vapors when it comes into contact with acids is forbidden. I hope this information is helpful. If we can be of further assistance, please contact us. Sincerely, 1. ' Susan Gorsky Acting Chief, Standards Development Office of Hazardous Materials Standards#
Page 2Aug. 20, 2 0 0 8 8 : 5 3 A M Hawkins, I n c . No. 2 6 4 1 P. 1 / 1 Corpomte g%cc 3100 East Hennepin Avenue Minneapolis, Minnesota 55413 Phone: (612) 331 -691 0 FOX: (612) 331-5304 August 20,2008 Mr. Edward T. Mazzullo Director, Office of Hazardous Materials Standards U.S. DOTIPHMSA (PHH-10) 400 7th Street S.W. Washington, D,C, 20590-0001 REQUEST FOR INTERYRETATION RE: 49 CFR 177.8481~) Dear Mr. Mazzullo: Scenario: There are 2 products to be shipped via truck (1 shipment) Product #1 is a 500# drm of Hydrochloric Acid (UN1789, Hazard Class 8, PGII) Product #2 i s Manox Blue Dye 1 SOD, which is a Non-DOT regulated material, which contains Ferric ferrocyanide (CAS#14038-43-8). The Material Safety Data Sheet for this product indicates that Hydrogen Cyanide gas can be evolved when it comes into contact with acids. 49 CFR 177.848(c) states: "In addition to the provisions of paragraph (d) of this section and except as provided in 9 173.1 2(e) of this subchapter, cyanides, cyanide mixtures or solutions may not be stored, loaded and transported with acids if a mixture of the materials would generate hydrogen cyanide, and Division 4.2 materials may not be stored, loaded and transported with Class 8 liquids." As Product #l is regulated, but Product #2 is not, does 177.848(c) apply? If you have any questions, 1 can be reached at 6 12-33 1-6910, x855 1 or at chris.Gibson@hawkinsinc.com Sincerely, Chris W. Gibson EBS&R Manager Hawkins, Inc. An Equal Opportunig Employer#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.