10-0173
10-0173
Page 1U.S. Department of Transportation Pipeline and Hazardous Materia~s Safety Administration 1200 New Jersey Ave, SE Washington, D.C. 20590 OCT 1 3 2010 Mr. Rich Byczek Site Manager Intertek 13200 Levan Road Livonia, MI 48150 Ref. No.: 10-0173 Dear Mr. Byczek: This is in response to your August 17,2010, email requesting clarification ofrequirements in the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to design-type testing of lithium ion batteries. In your email, you describe a lithium ion battery module comprised of electrically connected cells that serves as a component of a larger lithium battery pack. You state this lithium ion battery module is transported between manufacturing facilities and thus is subject to testing in accordance with the United Nations (l1N) Manual ofTests and Criteria. In your email, you note this module is equipped with a protective insulator that prevents external access to the battery terminals. You ask ifyou must remove the protective insulator to conduct the appropriate tests or note that the terminals are inaccessible. The specific requirements you address are contained in Section 38.3 ofthe UN Manual ofTests and Criteria and are implemented through the provisions of § 173.185 ofthe HMR. Prior to transportation in commerce, the lithium ion battery module must successfully pass all ofthe applicable tests in Section 38.3 ofthe UN Manual of Tests and Criteria, including the T.5 (short circuit test) and the T.7 (overcharge test). The lithium battery module must be subjected to all of the appropriate design type tests in the same configuration as when it will be installed in the larger battery pack. In this case if a physical barrier such as a cover must be removed prior to installation in the larger battery pack, it must be removed for design type testing. I hope this information is helpful. Ifyou have further questions, please contact this office. Sincerely, ~.5~ Ben Supko Acting Chief, Standards Development Office of Hazardous Materials Standards#
Page 2Drakeford. Carolyn (PHMSA) Learv{ §li3·-t~5 ~+h iu m ]!:a.tJert'e.s From: Betts, Charles (PHMSA) ID-O",~ Sent: Tuesday, August 17, 2010 9:53 AM To: Drakeford, Carolyn (PHMSA) Subject: FW: Interpretation requested regarding test applicability for Lithium -Ion Batteries Attachments: SN200241.jpg From: Rich Byczek Intertek [mailto:rich.byczek@intertek.com] Sent: Tuesday, August 17, 20109:46 AM To: Betts, Charles (PHMSA) Cc: Dawoomi Hong; Tom O'Hara Interteki Fadi Alawi Intertek Subject: Interpretation requested regarding test applicability for Lithium -Ion Batteries Charles, My name is Rich Byczek, and I am the site manager for Intertek's Safety and Performance lab in Detroit Michigan. I am writing you on behalf of our client, who had some questions related the UN Manual of Tests and Criteria, applicability of tests. Specifically, this client has a battery (rack of cells), which utilizes a protective insulator to prevent external access to the battery terminals (photo attached). It should be noted that this is an interim module-level part, the cells are electrically connected internal to the module, that is later connected as part of a full battery pack. This level does undergo transport between manufacturing facilities. As a test lab performing the testing, how should we treat this sample for the short circuit (T5) and overcharge (T7) tests. As the terminals are physically blocked, do I just note that the terminals are inaccessible, preventing an external short circuit or overcharge condition? Or, do I remove/bypass the protective cover to gain access to the terminals. Per client review, this feature is specifically added to prevent a short circuit or inadvertent voltage applied to the terminals. Therefore they consider it to be a protective device. The concern is validity of removing this device to perform the test, as this would be similar to bypassing a diode, fuse or other protective device. I can be contacted via email or Mobile phone. My contact information is listed below. Also, if there is a different contact I should use, please let me know. Thank you, Rich Byczek Site Manager Phone: 734-591-9161 Intertek 13200 Levan Road Livonia, MI48150 Fax: 734-432-0555 Mobile: 248-219-1099 Rich. Byczek@intertek.com www.intertek.com CONFIDENTIALITY NOTICE 1#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.