12-0252
12-0252
Page 1U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration 1200 New Jersey Avenue, SE Washington, D.C. 20590 JAN 0 7 2013 Mr. Ben Kadrlik CHART -SeQual Technologies, Inc. 2200 Airport industrial Drive, Suite 500 Ball Ground, GA 30107 USA Ref. No.: 12-0252 Dear Mr. Kadrlik: This responds to your November 2, 2012letter requesting clarification of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to a portable oxygen concentrator (POC). Specifically, you inquire about obtaining Federal Aviation Administration (FAA) approval to allow a passenger to carry the POC aboard an aircraft. According to your letter, the POC (trade name EQUINOX Oxygen System™) is a device that is for use by patients requiring high concentrations of oxygen on a supplemental basis. The maximum operating pressure of the EQUINOX Oxygen System™ is 23.7 pounds per square inch (psia). The EQUINOX Oxygen System™ is powered by multiple sources, including AC or DC power, and a rechargeable lithium-ion battery pack. For the EQUINOX Oxygen System™ powered by the rechargeable lithium-ion battery pack, the lithium-ion cells have a lithium content of 0.45 grams per cell, or 7.20 grams of aggregate equivalent lithium content for the battery pack. The lithium-ion battery packs are types designed to meet the appropriate tests in the United Nations Manual of Tests and Criteria, and the battery packs are packaged in a manner to prevent short circuits when offered for transport or carried onboard passenger aircraft. You ask whether this device is regulated under the HMR. Based on the information provided in your letter, the EQUINOX Oxygen System™ is not subject to the HMR as a Division 2.2 non-flammable gas. The lithium-ion battery pack appears to conform to § 172.102( c )(1 ), Special Provision 188 for the transportation of small lithium cells and batteries and the POC contains no other hazardous materials. Therefore, the EQUINOX Oxygen System™ is not subject to any other requirements in the HMR. Please note that notwithstanding the passenger exception in § 175.10(a)(18) of the HMR, Special Federal Aviation Regulation 106 (SFAR 106) "Rules for Use of Portable Oxygen Concentrator Systems on Board Aircraft" apply and are under the purview of the FAA, not the Pipeline and Hazardous Materials Safety Administration. This response letter satisfies#
Page 2only one requirement in the FAA approval process before a POC may be operated onboard an aircraft. You may contact Ms. DK Deaderick in FAA's Flight Standards Service at (202) 267-7 480 for questions regarding FAA's approval process. I hope this satisfies your inquiry. Please contact us if we can be of further assistance. Sincerely, ~--P~~--· T. Glenn Foster Chief, Regulatory Review and Reinvention Branch Standards and Rulemaking Division 2#
Page 3~ CAIRE~ CH.!JRT-Se(Jlu~:l Tecltnoloaies Inc. Suite 500 2200 Airport Industrial Drive Ball Ground, GA 30 107 Phone: 770.721.7700 Fax: 770.721.7701 www.chart-ind.com November 2, 2012 Mr. Charles Betts U.S. DOT PHMSA Office of Hazardous Materials Standards Attention: PHH-1 0 East Building 1200 New Jersey Avenue, SE Washington, DC 20590-0001 Re: Classification of Chart SeQual Technologies Inc. EQUINOX Oxygen System Dear Mr. Betts, I am writing to request written confirmation from the Pipeline and Hazardous Materials Safety Administration (PHMSA) that Chart SeQual Technologies Inc. new portable oxygen concentrator (POC) device known as the "EQUINOX Oxygen System" is not subject to the U.S. hazardous materials regulations (HMR). Background The EQUINOX Oxygen System is a device that separates oxygen from ambient air through a process called Pressure Swing Adsorption (PSA). The EQUINOX provides a solution to address both stationary and portable requirements for oxygen patients needing up to 3 LPM full flow operation and up to 192 ml flow in a pulse mode operation. It consists of a lightweight, portable oxygen concentrator with an integrated oxygen delivery valve for continuous flow or pulse delivery and is capable of being operated directly from an AC or DC power source or from rechargeable lithium ion batteries. It can be recharged and/or powered by a separate AC Power Adapter or where standard AC line power is available. A 12-Volt DC cable allows power to be provided by a DC auxiliary power outlet, such as in a motor vehicle during transportation. Changeable and rechargeable battery packs are available to provide a range of ambulatory operational time. The EQUINOX Oxygen System achieves its performance through SeQual's patented Advanced Technology Fractionator (ATF®) technology and patented variable speed compressor and compressor drive, advanced molecular sieve materials and rechargeable batteries. This system will expand an oxygen patient's ability to travel via aircraft and improve the patient's quality of life.#
Page 4~ C A I R E<, SEQ~: ' .~ ;;,· -<,-f -' 1 ~ ·~,._ ~,; CH.JlRT-SeQlutl Tecknolooies Inc. Suite 500 2200 Airport Industrial Drive Ball Ground, GA 30 107 Phone: 770.721.7700 Fax: 770.721.7701 www.chart-ind.com Class 2, Division 2.2 Gas - 49 CFR 173.115 The maximum pressure of the oxygen exerted within the EQUINOX Oxygen System packaging currently is 23.7 psia during normal operation at 20° C. This is substantially less than the 43.8 psia at 20° C referenced in 49 CFR 173 .115(b )(1) for defining a Division 2.2 gas. Therefore, it is our opinion that the oxygen exerted within the EQUINOX Oxygen System is not a Division 2.2 gas and thus is not subject to the U.S. HMR. Lithium ion Batteries- 49 CFR 173.185 The EQUINOX Oxygen System is powered by a lithium ion battery pack designed to be compliant with the UN Manual of Tests and Criteria. The batteries are housed in a single, sturdily constructed plastic enclosure. The entire battery pack consists of 16, 1,500 milli-ampere-hour lithium ion cells. Therefore, the pack contains an aggregate equivalent lithium content of 7.20 grams. Based on the requirements contained in 49 CFR 173.185, it is our opinion that the lithium ion battery pack is not subject to the HMR since the cells contain not more than 5 grams of equivalent lithium content, the battery pack contains not more than 25 grams of equivalent lithium content, the battery pack is of the type proven to be non-dangerous by testing in accordance with tests in the UN Manual of Tests and Criteria, and it will be packed in such a way to prevent short circuits when offered for transport or carried on board passenger aircraft. We also would like to point out that the U.S. HMR contain the following exception in 49 CFR 175.IO(a)(27) (as amended by PHMSA's Interim Final Rule HM-224E) for passengers and crew members: " ... consumer electronic and medical devices (watches, calculators, cameras, cellular phones, lap-top computers, camcorders, and hearing aids, etc.) containing lithium cells or batteries, and spare lithium batteries and cells for these devices, when carried by passengers or crew members in carry-on or checked baggage for personal use. In addition, each installed or spare battery must conform to the following: (i) The lithium content of the anode of each cell, when fully charged, is not more than 5 g; and (ii) The aggregate lithium content of the anodes of each battery, when fully charged, is not more than 25 g." This provision is generally consistent with one found in the ICAO Technical Instructions that authorizes consumer electronic devices containing lithium ion batteries with up to 25 grams of equivalent lithium content to be carried onboard passenger aircraft. * * * *#
Page 5CH.JlRT-SeQuctl Teclmolooies Inc. Suite 500 2200 Airport Industrial Drive Ball Ground, GA30107 Phone: 770.721.7700 Fax: 770.721.7701 www.chart:-ind.com I trust the information contained herein is sufficient for PHMSA to provide a written determination that the EQUINOX Oxygen System is not subject to the U.S. HMR. Should you need additional information or have any questions regarding our product, please do not hesitate to contact me at the information below. Our complete contact information is as follows: Chart SeQual Technologies fuc. 2200 Airport fudustrial Drive, Suite 500 Ball Ground, GA 30107 USA Attn: Ben Kadrlik - Regulatory Specialist Phone: 770-721-7700 FAX: 770-721-7701 Email: Ben.Kadrlik@chart-ind.com Best Regards, Ben Kadrlik Regulatory Specialist#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.