PI-74-0113
PI-74-0113
Page 1PI-74-0113 May 3, 1974 Mr. J. G. Osendorf, Utilities Engineer Minnesota Highway Department St. Paul, MN 55155 Dear Mr. Osendorf: This is with regard to the telephone conversation between Mr. Van Alstine of your office and Mr. Cesar DeLeon of the Office of Pipeline Safety concerning §192.111, 49 CFR. Mr. Van Alstine's interpretation of §192.111(b) is correct, that a steel pipe in a Class 1 location that crosses a public road without a casing must use a design factor of 0.60 or less in the design formula in §192.105. He is also correct in interpreting that a steel pipe in a Class 1 location that crosses a public road with a casing design in accordance with §192.105. I trust that this has answered Mr. Van Alstine's particular question. If we can be of further assistance, please let us know. Sincerely, Joseph C. Caldwell Director Office of Pipeline Safety 1#
This material provides agency context. It does not replace binding regulatory text, and its legal effect depends on the underlying authority and facts.