PHMSA-2016-0081
PHMSA-2016-0081
2016-0081-LOD-Renewal-for-Maurepas-Pipeline-State-Waiver.pdf, page 1Official PDFU.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration 1200 New Jersey Avenue, SE Washington, DC 20590 February 11, 2022 Mr. Michael Peikert Pipeline Division Assistant Director State of Louisiana Department of Natural Resources, Office of Conservation 617 North 3rd Street, 9th Floor Baton Rouge, Louisiana 70802 Re.: PHMSA-2016-0081 and Louisiana State Waiver PL Order No. 8379 Maurepas Pipeline, LLC – Waiver Renewal to December 31, 2026 Dear Mr. Peikert: On January 12, 2022, pursuant to 49 United States Code (USC) § 60118(d), the Pipeline and Hazardous Materials Safety Administration (PHMSA) received your letter that the Commissioner of Conservation in the Louisiana Department of Natural Resources (Commissioner) publicly noticed a State waiver renewal, PL Order No. 8379, on October 21, 2021. The Commissioner granted the waiver renewal on December 20, 2021, to Maurepas Pipeline, LLC, (Maurepas), pending a 60-day review and no objection by PHMSA. The Commissioner originally granted the State waiver, PL Order No. 7620, PHMSA-2016-008, on June 16, 2016, to Maurepas. The Commissioner issued the State waiver to Maurepas for variance from the cathodic protection (CP) requirements of 49 CFR § 195.563 for the operation of 35.7 miles of 12-inch diameter steel pipeline in St. James, St. John the Baptist, and St. Charles Parishes, Louisiana, to transport vacuum gas oil and connect Motiva’s Convent and Norco refineries. The Maurepas pipeline has an external jacket around the pipe that is impervious to moisture and CP. Pursuant to 49 USC § 60118(d), PHMSA does not object to this waiver renewal dated December 20, 2021, and effective until December 31, 2026, by the Commissioner for the Maurepas 35.7- mile pipeline facility between Motiva’s Convent and Norco refineries. I request that a copy of the Commissioner’s final waiver to Maurepas be forwarded to PHMSA within 30 days of issuance.#
2016-0081-LOD-Renewal-for-Maurepas-Pipeline-State-Waiver.pdf, page 2If you wish to discuss this or any other pipeline safety matter, my staff would be pleased to assist you. Please contact Sentho White, Director of Engineering and Research Division, at 202-366-2415, for technical matters. Sincerely, Alan K. Mayberry, Associate Administrator for Pipeline Safety PHMSA-2016-0081 – Louisiana PL Order No. 8379 Maurepas Pipeline, LLC – Waiver Renewal to 12/31/2026 Page 2 of 2#
lod-state-louisiana-maurepas-pipeline.pdf, page 1Official PDFof Transportation U.S. Department 1200 New Jersey Avenue, SE Washington, D.C. 20590 Materials Safety Pipeline and Hazardous Administration® AUG 1 1 2016 Mr. Steven Giambrone Pipeline Division Director State of Louisiana Department of Natural Resources Office of Conservation 617 North 3"d Street, 9' Floor Baton Rouge, Louisiana 70802 PHMSA-2016-0081 Dear Mr. Giambrone: On June 14, 2016, the Pipeline and Hazardous Materials Safety Administration (PHMSA) received a notice from the Commissioner of Conservation in the State of Louisiana, Department of Natural Resources, Office of Pipeline Safety (Louisiana Commissioner), informing us that after hearings on November 19, 2015, and April 21, 2016, in accordance with Section 3.2 of the "Guidelines for States Participating in the Pipeline Safety Program" a waiver was granted to Maurepas Pipeline, LLC, on June 13, 2016, (State of Louisiana, Office of Conservation, Pipeline Division, PL Order No. 7620), pending a 60-day review and no-objection by PHMSA. The Commissioner issued the State waiver to Maurepas Pipeline, LLC, for variance from the cathodic protection requirements of 49 CFR § 195.563, for the construction of 35.7 miles of 12- inch steel pipe in St. James, St. John the Baptist, and St. Charles Parishes, Louisiana, to connect Motiva's Convent and Norco refineries. The Maurepas pipeline is intended to transport vacuum gas oil (VGO) between the refineries and will eliminate the need for the product to be transported by barge. VGO becomes immobile as it cools and as such, insulation around the pipe must be utilized to keep the product warm enough to be transported by pipeline. Insulation, however, will render cathodic protection ineffective; therefore, Maurepas Pipeline, LLC, proposes to place a jacket (Viscotag) around the pipe that is impervious to moisture so that external corrosion cannot occur, thus eliminating the need for cathodic protection (CP). While the product has been utilized in pipelines in Europe, there is no known usage of Viscotag on a pipeline in the U.S. On July 27, 2016, the Commissioner provided PHMSA a modification to the order of June 13, 2016. PHMSA has "no objections" to the conditions of the Final Amended Order and accepts the "Order" as amended.#
lod-state-louisiana-maurepas-pipeline.pdf, page 2Page 2 Mr. Steven Giambrone State of Louisiana Department of Natural Resources My staff would be pleased to discuss this matter or any other regulatory matter with you. Mr. John Gale, Director of Standards and Rulemaking, may be contacted at 202-366-0434, on regulatory matters and Mr. Kenneth Lee, Director of Engineering and Research, may be contacted at 202-366-2094, on technical matters specific to this State Waiver. Sincerely, Acting Associate Administrator for Pipeline Safety#
This is a state-issued waiver listed by PHMSA after federal review. The historical grant does not establish current validity, renewal, facility applicability, or continuing effect.