Tenn. Comp. R. & Regs. 1220-04-05-.03
DEFINITIONS
(1)The following words and terms, when used in these rules, shall have the meaning indicated below:#
(a)Commission - Means the Tennessee Public Utility Commission of Tennessee.#
(b)Utility - Means any gas company operating under the jurisdiction of the Commission.#
(c)Customer - Means any person, firm, association, or corporation, or any agency of the Federal State, or local government, being supplied with gas service by a gas utility.#
(d)Premises - Means a piece of land or real estate, including buildings and other appurtenances thereon.#
(e)Gas Plant - Means all facilities owned by a gas utility for the production, storage, transmission, and distribution of gas.#
(f)Main - Means a gas pipe, owned, operated, or maintained by a utility which is used for the purpose of transmission or distribution of gas, but does not include “service pipe.”#
(g)Service Pipe - The pipe that runs between a main or a pipeline and a customer’s meter.#
(h)Meter - Without other qualifications, shall mean any device or instrument which is used by a utility in measuring a quantity of gas.#
(i)Check Flow - Means a flow between twenty percent (20%) and fifty percent (50%) of the rated capacity of a meter according to the manufacturer’s specifications.#
(j)Full Rated Flow - Means a flow of one hundred percent (100%) of the rated capacity of a meter according to the manufacturer’s specifications.#
(k)Cubic Foot - Cubic foot of gas as used in these rules shall have the following meanings.#
1.Where gas is supplied and metered to customers at the pressure (as defined in Rule 1220-04-05-.32) normally used for domestic customer’s appliances, a cubic foot of gas shall be that quantity of gas which, at the temperature and pressure existing in the meter, occupies one (1) cubic foot.#
2.When gas is supplied to customers at other than the pressure in (1.) above, the utility shall specify in its rules the base for measurement of a cubic foot of gas (see Rule 1220-04-06-.06(a)(2)(vi)). Unless otherwise stated, such cubic foot of gas shall be that quantity of gas, which at a temperature of sixty-eight degrees Fahrenheit (68°F) and a pressure of fourteen and seventy-three one hundredths (14.73) pounds per square inch absolute, occupies one (1) cubic foot.#
3.The standard cubic foot of gas for testing the gas itself for bearing value shall be that quantity of gas, saturated with water vapor, which at a temperature of sixty degrees Fahrenheit (60°F) and a pressure of thirty (30) inches of mercury occupies one (1) cubic foot. (Temperature of mercury two degrees Fahrenheit (2°F) acceleration due to gravity – thirty-two and seventeen one-hundredths (32.17) ft. per second; density – thirteen and five hundred ninety-five one- thousandths (13.595) grams per cubic centimeter)..03, continued)#
(l)Interruption of Service - Means any unplanned disturbance of the gas supply whereby the pilot flame on the appliances of at least fifty (50) customers shall have been extinguished.#
(m)The abbreviations used, and their meaning, shall be as follows: BTU - British Thermal Unit LP-Gas - Liquefied Petroleum Gas psig - Pounds Per Square Inch, Gauge W.C. - Water Column#