Regulationcurrent
WAC 480-75-390
Valve spacing and rapid shutdown.
Current as of 2008-06-30 Government source
Washington Utilities and Transportation CommissionOfficial agency material
View source (1)Each pipeline company must have procedures to rapidly locate and isolate reportable releases from its pipeline.#
(2)When determining the type of valve to be used, its location, and its shut-off time, each pipeline company must consider the following:#
(a)Terrain;#
(b)Geohazards;#
(c)Drainage; and#
(d)Type and condition of the pipe.#
(3)Whenever a pipeline company installs a new rapid shutdown valve, the pipeline company must conduct a surge analysis to ensure that the surge pressure in the pipeline will not exceed one hundred ten percent of the maximum operating pressure as a result of a rapid valve closure.#