Regulationhistorical
HAR 6-77-76
HAR 6-77-76 Limitations on welders
Snapshot 2026-08-12 Government source
Hawaii Public Utilities CommissionOfficial agency material
View source nondestructive testing may weld compressor station pipe and components. (b) No welder may weld with a particular welding process unless, within the preceding six calendar months, the welder has engaged in welding with that process. (c) A welder qualified under section 6-77-75(a) may not weld unless within the preceding six calendar months the welder has had one weld tested and found acceptable under section 3 or 6 of API Standard 1104, except that a welder qualified under an earlier edition previously listed in Appendix A may weld but may not requalify under that earlier edition. [Eff ] (Auth: HRS '269-6) (Imp: 49 C.F.R. '192.229, October 1, 1990)