49 CFR 173.420
Uranium hexafluoride (fissile, fissile excepted and non-fissile).
(a) In addition to any other applicable requirements of this subchapter, uranium hexafluoride, fissile, fissile excepted or non-fissile, must be offered for transportation as follows:
(1) Before initial filling and during periodic inspection and test, packagings must be cleaned in accordance with American National Standard N14.1.
(2) Packagings must be designed, fabricated, inspected, tested and marked in accordance with—
(i) American National Standard N14.1 (2001, 1995, 1990, 1987, 1982, 1971) (incorporated by reference, see § 171.7 of this subchapter) in effect at the time the packaging was manufactured;
(ii) Specifications for Class DOT-106A multi-unit tank car tanks (§§ 179.300 and 179.301 of this subchapter); or
(iii) Section VIII, Division I of the ASME Code (incorporated by reference, see § 171.7 of this subchapter), provided the packaging —
(A) Was manufactured on or before June 30, 1987;
(B) Conforms to the edition of the ASME Code in effect at the time the packaging was manufactured;
(C) Is used within its original design limitations; and
(D) Has shell and head thicknesses that have not decreased below the minimum value specified in the following table:
Packaging model Minimum thickness; millimeters(inches) 1S, 2S 1.58 (0.062) 5A, 5B, 8A 3.17 (0.125) 12A, 12B 4.76 (0.187) 30B 7.93 (0.312) 48A, F, X, and Y 12.70 (0.500) 48T, O, OM, OM Allied, HX, H, AND G 6.35 (0.250)
(3) Uranium hexafluoride must be in solid form.
(4) The volume of solid uranium hexafluoride, except solid depleted uranium hexafluoride, at 20 °C (68 °F) may not exceed 61% of the certified volumetric capacity of the packaging. The volume of solid depleted uranium hexafluoride at 20 °C (68 °F) may not exceed 62% of the certified volumetric capacity of the packaging.
(5) The pressure in the package at 20 °C (68 °F) must be less than 101.3 kPa (14.8 psia).
(b) Packagings for uranium hexafluoride must be periodically inspected, tested, marked and otherwise conform with the latest incorporated edition of ANSI N14.1 (incorporated by reference, see § 171.7 of this subchapter).
(c) Each repair to a packaging for uranium hexafluoride must be performed in accordance with the latest incorporated edition of ANSI N14.1 (incorporated by reference, see § 171.7 of this subchapter).
[Amdt. 173-244, 60 FR 50307, Sept. 28, 1995, as amended at 67 FR 61014, Sept. 27, 2002]