Regulationcurrent
RCSA § 16-280b-B26
Odorization of Gas
Current as of 2025-06-11 Government source
Connecticut Public Utilities Regulatory AuthorityOfficial agency material
View source (a)The periodic sampling required pursuant to 49 CFR 192.625(f), as amended from time to time, shall be performed:#
(1)at least once each calendar month, but at intervals not exceeding 45 calendar days; and#
(2)at locations where Gas flow may affect odorant concentrations.#
(b)Not later than January 1, 2037, each Gate Station shall contain equipment to introduce odorant properly and safely into each Pipeline.#
(c)Each Operator shall ensure there is adequate odorant and odorant sampling when a new Main is Placed In Service or when portable compressed natural Gas or liquefied natural Gas is introduced into any Pipeline.#