Regulationcurrent
LAC 43:XIII §1919
Service Lines: Connections to Cast Iron or Ductile Iron Mains [49 CFR 192.369]
Current as of source date Government source
Louisiana Office of ConservationOfficial agency material
View source (A)A. Each service line connected to a cast iron or ductile iron main must be connected by a mechanical clamp, by drilling and tapping the main, or by another method meeting the requirements of §1503. [49 CFR 192.369(a)]#
(B)B. If a threaded tap is being inserted, the requirements of §1111.B and C must also be met. [49 CFR 192.369(b)]#
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.#
HISTORICAL NOTE: Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:234 (April 1983), amended LR 10:527 (July 1984), LR 30:1250 (June 2004).#