Regulationcurrent
LAC 43:XIII §2129
Internal Corrosion Control: Monitoring [49 CFR 192.477]
Current as of source date Government source
Louisiana Office of ConservationOfficial agency material
View source (A)A. If corrosive gas is being transported, coupons or other suitable means must be used to determine the effectiveness of the steps taken to minimize internal corrosion. Each coupon or other means of monitoring internal corrosion must be checked two times each calendar year, but with intervals not exceeding seven and one-half months. [49 CFR 192.477]#
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.#
HISTORICAL NOTE: Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:237 (April 1983), amended LR 10:529 (July 1984), LR 30:1255 (June 2004).#